Load Bearing Test
For 6 m span bridge application 3 panels are placed and tied. 6 mm diameter steel mesh reinforcement is applied on Zenon Panels.
10 cm thick 30 MPa concrete is poured over the Zenon Panel slab. Two weeks after concreting the formwork under the panel are removed and the test is performed with cylinder machine that has 15 tons self-weiht and 39 tons total weight with vibration .